Laws

Murang kuryente Act
RA 11371
RA 11361
RA 10912
RA 11285
Anti Obstruction of Powerlines Act
RA 11361
RA 9513
RA 11285
RA 11058
CPD Act
RA 10912
RA 11058
RA 11285
RA 9513
Renewable Energy Act
RA 9513
RA 11058
RA 10912
RA 11285
Energy Efficiency and Conservation Act
RA 11285
RA 10912
RA 11058
RA 9513
Compliance with OSHS
RA 11058
RA 7832
RA 11393
RA 6969
Act Penalizing of Pilferage of Electricity
RA 7832
RA 6969
RA 11393
RA 11371
Advance Energy and Green Building Technologies Curriculum Act
RA 11393
RA 7832
RA 11371
RA 10912
Toxic Substances and Hazardous Nuclear Wastes Control Act of 1990
RA 6969
RA 10912
RA 11371
RA 7832
Philippine Qualification Framework Act
RA 10968
RA 7832
RA 10912
RA 6969
If two or more buildings are supplied by a grounded by a grounded system from one main service, each building shall have separate
Phases
Neutrals
Grounding electrode systems
Service drops
A cable provided with a wrapping or metal usually steel wires or tapes, primarily for the purpose of mechanical protection
Metal clad cable
Metallic sheathed cable
Armored cable
flat conductor cable
In all cases where there are energized parts on the front of the switch boards or motor control centers, the working space in front of such equipment shall NOT be less thanminimum distance. What is this distance?
2000mm
500mm
1500mm
1000mm
Border lights shall be installed around stages in theaters on circuits rated at_____ less
20A
15A
30A
10A
Conductors supplying a heating unit shall be calculated at ____ percent times theheating load plus the blower motor
100
130
125
110
In order to protect a personnel and prevent shock, the equipment should be connected good earth ground through the
Conduit pipe
Hot water pipe
Cold water pipe
Rigid conduit pipe
A photovoltaic power source having one conductor of a 2-wire system over _____volts shall be solidly grounded
100
150
50
200
What is the minimum size of the aluminum or copper clad aluminum conductors, used as service entrance conductors?
8.0 mm^2
5.5 mm^2
14 mm^2
3.5 mm^2
The unit lighting for a dwelling unit expressed in watts per square meter shall be
8 watts
40 watts
24 watts
16 watts
In dwelling units, when the actual number of receptacle outlet is not known, anadditional load of ____ volt-ampere per square meter shall be included
10
4
8
6
Hoistways of elevators serving more than ___ floors shall be provided a means of venting smoke and hot gases to the outer air in case of fire
Three
Five
Two
Four
In which Occupational Safety And Health Standards (OSHS) rule Electrical Safety belong?1
1220
1230
1210
1200
The duration of temporary certificate of installation for construction work and installation pending permanent installation shall be a period of ____ days from date of issuance subject to renewal until the work is completed
Sixty days (60)
One hundred twenty (120) days
Ninety (90) days
Thirty (30) days
Standard railings shall be at least from the floor level to the upper surface of the top rail
1 meter (3.3 t.)
1.5 m (4.9 f.t)
2m (6.6 ft)
3 m (9.8 ft)
A wall openings less than 1 meter (3.3 ft) from the floor, having a height of at least 75 cm (30inch) and a width of at least 45 cm (18 inch) from which there is a drop of more than two (20 meters (6.6 ft) shall be solidly enclosed or guarded by barriers capable of with standing a load of at least ____ applied in any direction at any point of the top rail or corresponding members except vertically upward
100 kgs
1 ton
200 kgs
50 kgs
A toe boards shall be securely fastened in place, with not more than ___ clearance above floor level.
6 mm
8 mm
10 mm
15 mm
In demolition safety, this control is characterized by ensuring separation between the public and the demolition activities
Isolation
Elimination
Substitution
Engineering Control
An Act strenghthening compliance with occupational safety and health (OSH) standards and providing penalties for violations thereof.
DOLE department Order no. 198 s.2018
DOLE department Order no. 13, s. 1998
Republic Act no. 11508
Republic Act no. 11058
Primary cause of accident that is characterized by the human action that departs from a standard or written job procedure or common practice, safety rules, regulations, or instructions
Unsafe Act
Unsafe Condtion
Safety Hazard
Health Hazard
An engineering control or PPE set that protect you after you fall which is characterized by stopping the fall before you hit the surface like net/mesh and/or body harness.
Fall alert system
Fall-proof system
Fall arrest system
Fall protection syste,
{"name":"Laws", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Murang kuryente Act, Anti Obstruction of Powerlines Act, CPD Act","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}
Make your own Survey
- it's free to start.