SOP Adherence Campaign 2022-23

A visually engaging graphic depicting LPG safety procedures, equipment, and standard operating protocols, showcasing a safe industrial environment with clear signage and professional workers in action.

SOP Adherence Quiz 2022-23

Welcome to the SOP Adherence Campaign Quiz for the year 2022-23! This quiz is designed to test your understanding of the Standard Operating Procedures (SOP) related to LPG operations and safety measures. Enhance your knowledge and ensure adherence to safety protocols by participating.

The quiz covers a range of important topics including:

  • Safety measures in LPG handling
  • Hydrostatic testing procedures
  • Cylinder specifications and regulations
  • Equipment requirements and maintenance

26 Questions6 MinutesCreated by ProtectiveSeal421
EMPLOYEE NAME
FOR DEGASSING, THE CYLINDER SHOULD BE DEPRESSURISED UPTO WHAT PRESSURE?
2 kg/cm2
1.5 kg/cm2
NEAR ATMOSPHERIC PRESSURE.
3 KG/SQCM
DURING HYDRO TESTING OF LPG HOSES, PERMANENT ELONGATION IS MORE THAN _____ WHEN COMPARED TO THE ORIGINAL LENGTH THE HOSE SHOULD BE DISCARDED FROM LPG SERVICE.
0.1
0.02
0.04
0.05
FOR STORAGE WATER TANK, IT SHOULD BE ENSURED THAT THE ANNULAR PLATE AT THE BOTTOM OF THE TANK IS CLEAR OF __________________ .
WATER
DEPOSITS
VEGETATION.
ALL OF THEM
CALORIFIC VALUE OF LPG IS _________ K CAL/KG.
10500
12800
10900
14000
FOR TESTING LPG PIPELINE A TEST PRESSURE OF AT LEAST ____ TIMES THE WORKING PRESSURE SHOULD BE APPLIED.
2
3
1.5
2.5
WHAT IS THE HYDROSTATIC TEST PRESSURE TO WHICH SC VALVE BODIES (REPRESENTAIVE SAMPLES) ARE SUBJECTED TO?
25.35 KGF/SQCM.
15.35 KGF/SQCM.
16.35 KGF/SQCM.
14.35 KGF/SQCM.
WARNING WHISTLE OF SCABA BLOWS -------- MINUTES BEFORE EXHAUST OF AIR
10 MINUTES
20 MINUTES
25 MINUTES
15 MINUTES
WHAT IS THE MINIMUM DURATION FOR WHICH THE TEST PRESSURE HAS TO BE MAINTAINED DURING THE HYDROSTATIC TEST OF LPG ABOVE GROUND PIPELINES?
30 MINUTES
TWO HOURS
THREE HOURS.
FOUR HOURS.
WHAT SHOULD BE THE MINIMUM TENSILE STRENGTH OF THE VALVE MATERIAL?
30 KGF/SQ MM
20 KGF/SQ MM
10 KGF/SQ MM
40 KGF/SQ MM
WHAT IS THE OVERALL HEIGHT OF THE 14.2 KG CYLINDER/
620 +- 5 MM
630 +- 5 MM
625 +- 5 MM
645 +- 5 MM
WATER DRAIN LINE, THE FIRST VALVE NEARER TO STORAGE VESSEL SHOULD BE OF __________ TYPE AND THE AWAY FROM THE STORAGE VESSEL SHOULD BE OF _________ TYPE.
QUICK SHUT, THROTTLE TYPE
THROTTLE TYPE, QUICK SHUT
BALL TYPE, THROTTLE TYPE
ANY OF THEM
RELIEVING CAPACITY OF SAFETY VALVE
100% RELIEVING CAPACITY
110% RELIEVING CAPACITY
150% RELIEVING CAPACITY
NONE OF THE ABOVE.
WHO IS AUTHORIZED TO SIGN THE HOT WORK PERMIT?
SAFETY OFFICER
OFFICER IN CHARGE OF WORK
LOCATION IN CHARGE
NONE OF THE ABOVE.
WHERE IS A TSV FITTED?
ON LIQUID LINE
ON VAPOUR LINE
ON BOTH LINES
NONE OF THE ABOVE.
CYLINDER SHALL BE CONDEMNED IF THE MEAN DIAMETER OF THE DENT IS GREATER THAN ________ OF THE DIAMETER OF THE CYLINDER
1/4TH
1/10TH
2/3RD
3/4TH
THE FIRE WATER RING MAIN SHOULD BE CHECKED ONCE IN A _______ FOR THE LEAKS ETC. BY OPERATING ONE OR MORE PUMPS WITH THE HYDRANT POINTS KEPT CLOSED AS REQUIRED TO GET THE MAXIMUM OPERATING PRESSURE.
MONTH
WEEK
FORTNIGHT
YEAR
COLOUR CODE OF INSTRUMENT AIR PIPE-LINE IS
GREEN
GREY
BLACK
BLUE
WHAT IS FILLING RATIO?
RATIO OF WEIGHT OF LPG TO THE WEIGHT OF WATER AT 15 deg C
RATIO OF WEIGHT OF LPG AT 85% TO FULL WEIGHT
RATIO OF WEIGHT OF WATER TO 85% LPG WEIGHT OF THE SAME CONTAINER
RATIO OF WEIGHT OF WATER TO 85% LPG WEIGHT OF THE SAME CONTAINER
LOW TEMPERATURE SUITS ARE USED IN :
TERMINALS
AFS
LPG PLANTS
LUBE PLANTS
LPG CYLINDER VALVE SHOULD PERFORM SATISFACTORILY OPENING & CLOSING OPERATION NOT LESS THAN :
1000 CYCLES
5000 CYCLES
3000 CYCLES
2000 CYCLES
SET PRESSURE OF SAFETY VALVE OF 75 KG TROLLEY MOUNTED DCP EXTINGUISHERS SHALL BE
16.7 KG/CM2
15.9 KG/CM2
17.0 KG/CM2
25.0 KG/CM2
ETP STANDS FOR
EMISSION TREATMENT PLANT
EFFLUENT TESTING PLANT
EFFLUENT TREATMENT PLANT
ENERGY TIMING PROCESS
TENURE OF THE MEMBERS OF “ SAFETY COMMITTEE” IN A FACTORY AS PER FACTORIES ACT?
1 YEAR
2 YEARS
3 MONTHS
6 MONTHS
PRESSURE SWITCHES, TEMPERATURE GAUGES, TEMPERATURE SWITCHES, LEVEL SWITCHES & OTHER TRIPS AND ALARMS IN THE PLANT HAVE TO BE TESTED AND CALIBRATED ONCE IN ________.
Quarter
Six Month
Year
Two Years
Warning level of GMS?
35% of LEL
20% of LEL
60% of LEL
55% of LEL
{"name":"SOP Adherence Campaign 2022-23", "url":"https://www.supersurvey.com/QPREVIEW","txt":"Welcome to the SOP Adherence Campaign Quiz for the year 2022-23! This quiz is designed to test your understanding of the Standard Operating Procedures (SOP) related to LPG operations and safety measures. Enhance your knowledge and ensure adherence to safety protocols by participating.The quiz covers a range of important topics including: Safety measures in LPG handling Hydrostatic testing procedures Cylinder specifications and regulations Equipment requirements and maintenance","img":"https:/images/course3.png"}